Hi, Reader

Welcome to my blog that talk all about radiography and sonography

Monday, August 06, 2012

Dual Energy Toshiba Aquilion™ PRIME CT Scan Review, 160 Slice Specs and Price

The most important clinical benefit proved ability to scan given anatomic volume within a given scan time with substantially reduced slice width at M times increased longitudinal resolution. This way , for many clinical application the goal of isotropic resolution was within reach with 164 slice CT Scan System. Examination of entire thorax or abdomen could now routinely be performed a 1mm or 1,25 mm collimated slice width. Aquilion PRIME is a brand new multislice helical CT system with an 80-row sensor capable of generating A hundred and forty slices per rotator using the coneXact reconstruction formula. Highspeed rotation allows quick data acquisition as well as shortens scan occasions, while the fast renovation unit further increases throughput, reducing the time necessary for diagnosis. Aquilion PRIME could be the latest addition to the particular Aquilion ONE family along with key features like ”Adaptive Iterative Dose Decline 3D” (AIDR 3D), an repetitive reconstruction algorithm that has been designed to further improve clinical examinations.

160 Multi Slice CT also dramatically expanded into areas previously considered beyond the scope of four generation CT scanner based on the mechanical rotation of the x ray tube, such as cardiac imaging with addition of ECG gating capability. Dual-energy helical scanning alternates between everywhere kV with each gantry rotation. Your mA is also routinely adjusted for the a pair of different energies to make sure a matched indication to noise ration which usually increases the accuracy of dual energy investigation. In addition, Aquilion PRIME automatically turns X-ray exposure away from as the X-ray tube moves the front of the patient, thus minimizing contact with radiosensitive organs such as the breasts and eye contact. Dual Energy CT was initially explored and described by Godfreyhoundfiled, who stated in 1973,”two pictures are taken in same slice, one at 100 kV and other at 140kV..so that areas of high atomic numbers can be enhanced. Test carried out date have shown that iodine(z=53)n can be readily differentiated from calcium (z=20)’(Hounsfield, 1973). It has always been an aim to collect as much information as possible for differentiation of tissues

The Key features of AIDR 3D on Toshiba Aquilion PRIME :

  • Full integration in scan protocols for improved workflow
  • Dose reduction in clinical setting  by up to 75%
  • Full automatic iterative reconstruction process
  • Minimal penalty in reconstruction times
  • Noise reduction and improved Spatial Resolution
  • Superb artifact suppression

Toshiba Aquilion PRIME ensures quickly data to medical diagnosis that meets the requirements of more and more complex examinations and accelerate the process of supplying the information you need to make remedy decisions.

  • Fast Reconstruction
  • 80-detector row helical
  • 78 cm gantry aperture
  • Metal less Head rest
  • Metal less Arm up holder
  • SUREXtension™*

Exposure reduction and excellent image quality   

body perfusion toshiba dual energy aquillion primeBody perfusion software analyzes the blood perfusion of the organ from energetic scan images.
The perfusion application can provide more details for the diagnosis, treatment method and follow up involving lesions.lung analysis dual energy toshiba aquilion prime 160 slice

Lung volume analysis instantly identifies tissues within the lung fields with a CT quantity lower than the specified benefit (regions of pulmonary emphysema) for visualization and examination.

No comments: