Hi, Reader

Welcome to my blog that talk all about radiography and sonography

Wednesday, August 08, 2012

Agfa CR 30-X Review , Specs and Price

Compact, tabletop digitizer for computed radiography where space is limited or in mobile environments. The AGFA CR 30-X had been built for a private as well as decentralized computed radiography environment, which include emergency, ICU, dental, chiropractic care, orthopedic, military discipline hospital and vet applications. This Agfa model produces high resolution photographs, reading imaging china at ten pixels/mm irrespective of plate size. It's a compact size and can provide in the x-ray room or perhaps, with a mobile equipment, is appropriate for use inside mobile situations. This specific Agfa equipment requires absolutely no special electrical shops in order to function, so that you can be up and running with it which has a single day's installing.

Key benefits
  • Proven technologies offering consistent image quality
  • Suitable for a broad range of applications
  • Table-top format easy to position in small spaces and suited for mobile applications

PRICE

Under $ 20000

SPECIFICATION

Digitizer type
Single cassette feed
Throughput:
35 x 43 cm (14 x 17") = approx. 60 plates/hour
35 x 35 cm (14 x 14") = approx. 60 plates/hour
24 x 30 cm (9.5 x 12") = approx. 71 plates/hour
18 x 24 cm (7 x 9.5") = approx. 76 plates/hour
15 x 30 cm (6 x 12") = approx. 82 plates/hour
Display
LED Status Indicator
Status and error messages on external PC monitor
Grayscale resolution
Data acquisition: 20 bits/pixel
Output to processor: 16 bits/pixel
Dimensions and weight
W x D x H: 693 x 701 x 464 mm (27.2 x 27.6 x 18.2")
Depth including input tray: 769 mm (30.3")
Weight: approx. 80 kg (176.37 lbs)
Power
220 -240 V/50-60 Hz, standby 120 W, max. 320 W, 16A fuse
120 V/60 Hz (USA), standby 120 W, max. 320 W, 15A fuse
100 V/60 Hz (Japan), standby 120 W, max. 320 W, 15A fuse
Minimum requirements
CR MD 4.0T General Cassette
CR MD 4.0 General Plate
NX
Environmental conditions
Temperature: 15-30°C (59 - 86°F)
Humidity: 15-80% RH
Magnetic fields: max. 3.8 μT in conformance with EN 61000-4-8: level 2
Rate of change of temperature: 0.5°C/minute (0.9°F)
Environmental effects
Noise level: max. 65 dB (A)
Heat dissipation: standby 120 W, max. 320 W

SAFETY
Approvals
UL, cUL, CE
Transport details
Temperature: -25 to +55°C (-4 to 131°F),
-25°C for max. 72 hours, +55°C for max. 96 hours
Humidity: 5-95% RH

Image sample

CR 30-X agfa

No comments: