Hi, Reader

Welcome to my blog that talk all about radiography and sonography

Thursday, June 14, 2012

CT Scanner Technologies Highlighted at SCCT

Since the kVP rise and fall are incorporated into view measurement , a fast switching generator is required, and any reaming low level non idealities are accounted for in the spectral calibration of the data. In order to combat the traditional flux issues that have challenged fast kV switching , low kVp and high kVp acquisitions are flux balanced through advances in the DAS, which allow for dynamically changing view integration times. Additional time allocated to low kVp acquisition relative to the high kV acquisition in oreder to reduce photon starvation conditions. Coupled with the appropriate rotation speed , amore balanced flux condition between the two kVp scans is achieved and serves to minimize patient dose. Fast kV switching scans have designed to minimize the additional dose relative to single energy scans, In a recent dose and low contrast detectability (LCD) comparison(Li et al, 2010), the effectiveness of this sampling scheme with respect to dose was demonstrated by matching the LCD at as a slice thickness equal to 5 mm and object of 3 mm.

The Aquilion Perfect system has an 80-slice sensor, but can be improved in the field to some 180-slice system.Computed tomography (CT) suppliers highlighted several current improvements to their image resolution systems during the Next year Society of Cardio CT (SCCT) annual scientific conference in July within Baltimore, Md. 

GE outlined its Discovery CT750 High definition FREEdom scanner, that provides a new type of sensor for better signal-to-noise percentages and new renovation software to reduce sewing artifacts and sound of low-dose scans. Additionally, it offers the ability to carry out dual energy tests using a single X-ray pipe modulated every 0.Five milliseconds between 80 as well as 140 kVp.

The system’s Independence (Fast Registered Powers and ECG) software provides intelligent motion modification via SnapShot Deep freeze, enhanced coronary visualization even just in the presence of calcium, comprehensive plaque material make up assessment and correct perfusion calculations. SnapShot Deep freeze is supposed to significantly decrease coronary motion and conquer the limitation of hardware-only solutions. It specifically detects vessel movement and velocity as well as determines actual charter boat position and can make corrections.

“SnapShot Freeze is a game changer by increasing the effective temporal quality, and from the preliminary images, I see considerably reduced motion items and significantly enhanced image clarity,” stated James Min, overseer of cardiac image resolution research and co-director associated with cardiac imaging from Cedars Sinai Hospital and present president of SCCT. He's a principal detective for the VICTORY test, which is evaluating the actual diagnostic accuracy associated with SnapShot Freeze movement and stitching madame alexander doll correction.

Toshiba’s newest CT product is the Aquilion Prime, the replacement for its prior 64-slice system. It is an 80-slice program that can be upgraded within the field over a weekend break to a 180-slice system. It provides a 78 millimeters bore and has 660-pound capability tables to accommodate bigger patients.

Earlier this year, Siemens launched the new Stellar sensor for its CT systems, which utilizes integrated, printed microcircuits rather than soldered circuit boards. This particular reduces the amount of digital noise in tests by about 20 %. The new detectors additionally overall improve picture quality by reducing calcium supplement and metal blossoming, so it is easier to assess in-stent restenosis.Noise suppression is automatically Applied to GSI imaging and is used on the material density images in order to enhance the quality of the image without shifting the mean values. This allows for a quantities material density image with good image quality. The noises suppression it self leverages the statistical iterative reconstruction approach taken by ASIR(fan et al,2010).

No comments: